Control set, DOSINACO™

Reagent Kit

  • Product Number: 227-40520
  • Component of DOSINACO™ reagent kit

DOSINACO™ is intended for research use only, not for diagnostic.

Make a request
Select a quantity:

Description

DOSINACO™ Control Set is used to quantify 9 anticoagulants in human plasma by LC-MS/MS method.
The set is composed by 4 quality controls with different concentration levels. The kit contains all material needed to quantify the anticoagulant drugs.

Product available for RUO 227-40520-58 (Europe) / 227-40520-91 (Japan)

Technical Data

Content: 4 control level (lyoph.) (4x500 µL)
Parameters: Acenocoumarol, Apixaban, Argatroban, Betrixaban, Dabigatran, Edoxaban, Fluindione, Rivaroxaban and Warfarin.

Concentration: (µg/L)

Level 1Level 2Level 3Level 4
Parameters Value Limits Value Limits Value Limits Value Limits
Acenocoumarol 200 150 - 250 1000 800 - 1200 2000 1600 - 2400 4000 3200 - 4800
Apixaban 20 15 - 25 100 80 - 120  200 160 - 240 400 320 - 480
Argatroban 20 15 - 25 100 80 - 120 200 160 - 240 400 320 - 480
Betrixaban 20 15 - 25 100 80 - 120 200 160 - 240 400 320 - 480
Dabigatran 20 15 - 25 100 80 - 120 200 160 - 240 400 320 - 480
Edoxaban 20 15 - 25 100 80 - 120 200 160 - 240 400 320 - 480
Fluindione 200 150 - 250 1000 800 - 1200 2000 1600 - 2400 4000 3200 - 4800
Rivaroxaban 20 15 - 25 100 80 - 120 200 160 - 240 400 320 - 480
Warfarin 200 150 - 250 1000 800 - 1200 2000 1600 - 2400 4000 3200 - 4800

Storage: refer to the Instruction for use (please login to consult your document)


Comment: Control Set DOSINACO™ is delivered with a safety data sheets to use properly the product.